Wyłącznik mocy 3-bieg. 250A BG2

  • szt.
  • Discount: -2,911.82 zł (40 %)
  • (Gross discount: -3,581.54 zł (40 %))
  • Gross price: 5,372.32 zł / szt. 4,367.74 zł / szt.

Wyłącznik mocy 3-bieg. 250A BG2 NZMH2-A250

Program
Range
    Circuit-breaker
Protective function
    System and cable protection
Photovoltaic applications
Standard/Approval
    IEC
Installation type
    Fixed mounted
Release system
    Thermomagnetic release
Construction size
    NZM2
Number of conductors
    3 pole
Standard equipment
    Screw connection
Switching capacity
     
400/415 V 50/60 Hz
Icu kA 150
Rated current = rated uninterrupted current
     
Rated current = rated uninterrupted current
In= Iu A 250
Setting range
     
Overload trip
     
Overload releases
Ir A 200- 250
Short-circuit releases
     
Non-delayed
Ii= Inx …   6 - 10
 
General
Standards
    IEC/EN 60947
Protection against direct contact
    Finger and back of hand proof to VDE 0106 Part 100
Climatic proofing
    Damp heat, constant to IEC 60068-2-78
Damp heat, cyclic to IEC 60068-2-30
Ambient temperature
  °C  
Ambient temperature, storage
  °C -40- +80
Operation
  °C -25… +70
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27
  g 20 (half-sinusoidal shock 20 ms)
Safe isolation to VDE 0106 Part 101 and Part 101/A1
     
Between auxiliary contacts and main contacts
  V AC 500
between the auxiliary contacts
  V AC 300
Weight
  kg 2.345
Mounting position
     
Mounting position
   
Vertical and 90° in all directions
With residual-current release XFI:
- NZM1, N1, NZM2, N2: vertical and 90° in all directions
with plug-in adapter elements
- NZM1, N1, NZM2, N2: vertical, 90° right/left
with withdrawable unit:
- NZM3, N3: vertical, 90 ° left
- NZM4, N4: vertical
with remote operator:
- NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90° in all directions

 

Direction of incoming supply
    As required
Degree of protection
     
Device
    In the operating controls area: IP20 (basic degree of protection)
Enclosures
    With insulating surround: IP40, with door coupling rotary handle: IP66
Terminations
    Tunnel terminal: IP10
Phase isolator and strip terminal: IP00
Other technical data (sheet catalogue)
    Weight
Temperature dependency, Derating
Effective power loss
Circuit-breakers
Rated current = rated uninterrupted current
In= Iu A 250
Rated surge voltage invariability
Uimp    
Main contacts
  V 8000
Auxiliary contacts
  V 6000
Rated operational voltage
Ue V AC 690
Rated operational voltage
Ue V DC 750
 
   

1) Details apply for 3 pole system protection circuit-breaker with thermomagnetic release NZMN(H)1(2)(3)-A... to 500 A.

For rated operating voltage switching via 3 contacts:

DC correction factor for instantaneous release response value: NZM1: 1.25, NZM2: 1.35, NZM3: 1.45

Set value for Iiat DC = set value IiAC/correction factor DC

Switching of one pole via two series contacts   Switching of one pole via three series contacts
 
Overvoltage category/pollution degree
    III/3
Rated insulation voltage
Ui V 1000
For use in IT electrical power networks
  V 690
Switching capacity
Rated short-circuit making capacity
Icm    
240 V
Icm kA 330
400/415 V
Icm kA 330
440 V 50/60 Hz
Icm kA 286
525 V 50/60 Hz
Icm kA 105
690 V 50/60 H
Ic kA 40
Rated short-circuit breaking capacity Icn
Icn    
Icu to IEC/EN 60947 test cycle O-t-CO
Icu kA  
240 V 50/60 Hz
Icu kA 150
400/415 V 50/60 Hz
Icu kA 150
440 V 50/60 Hz
Icu kA 130
525 V 50/60 Hz
Icu kA 50
690 V 50/60 Hz
Icu kA 20
500 V DC
Icu kA 60
750 V DC
Icu kA 60
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO
Ics kA  
240 V 50/60 Hz
Ics kA 150
400/415 V 50/60 Hz
Ics kA 150
440 V 50/60 Hz
Ics kA 130
525 V 50/60 Hz
Ics kA 37.5
690 V 50/60 Hz
Ics kA 5
Maximum low-voltage h.b.c. fuse
  A gG/gL 355
 
    Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker.
Rated short-time withstand current
     
t = 0.3 s
Icw kA 1.9
t = 1 s
Icw kA 1.9
Utilization category to IEC/EN 60947-2
    A
Rated making and breaking capacity
     
Rated operational current
Ie A  
AC-1
     
400 V
Ie A 300
415 V
Ie A 300
690 V
Ie A 300
AC--3
     
400 V
Ie A 250
415 V
Ie A 250
690 V
Ie A 250
DC - -1
     
500 V DC
Ie CSA 250
750 V DC
Ie CSA 250
DC - 3
     
500 V DC
Ie CSA 250
750 V DC
Ie CSA 250
Lifespan, mechanical(of which max. 50 % trip by shunt/undervoltage release)
Operations   20000
Lifespan, electrical
     
AC-1
     
400 V V 50/60 Hz
Operations   10000
415 V V 50/60 Hz
Operations   10000
690 V 50/60 Hz
Operations   7500
AC--3
     
400 V 50/60 Hz
Operations   6500
415 V 50/60 Hz
Operations   6500
690 V 50/60 Hz
Operations   5000
DC - -1
     
500 V DC
  Operations 7500
750 V DC
  Operations 7500
DC - 3
     
500 V DC
Operations   3000
750 V DC
Operations   3000
Max. operating frequency
  Ops/h 120
Current heat losses per pole at Iuare based on the maximum rated operational current of the frame size.
  W 19
 
    For current heat loss per pole the specification refers to the maximum rated operational current of the frame size.
Total downtime in a short-circuit
  ms < 10
Terminal capacity
Standard equipment
    Screw connection
Overview
   
Basic equipment                
  Box terminal     -   -   -
  Screw connection   -      
Accessories                
  Box terminal   -       -
  Screw connection     -   -  
  Tunnel terminal        
  Connection on rear        
  Flat conductor terminal   -   -   -  
Round copper conductor
     
Box terminal
     
Solid
  mm2 1 x (4 - 16)
2 x (4 - 16)
Stranded
  mm2 1 x (25 - 185)
2 x (25 - 70)
Tunnel terminal
     
Solid
  mm2 1 x 16
Stranded
  mm2  
Stranded
  mm2 1 x (25 - 185)
Bolt terminal and rear-side connection
     
Direct on the switch
     
Solid
  mm2 1 x (4 - 16)
2 x (4 - 16)
Stranded
  mm2 1 x (25 - 185)
2 x (25 - 70)
Al conductors, Cu cable
     
 
     
Solid
  mm2 1 x 16
Stranded
  mm2  
Stranded
  mm2 1 x (25 - 185)
je nach Kabelhersteller bis zu 240 mm² anschließbar
Bolt terminal and rear-side connection
     
Flat copper strip, with holes
min. mm 2 x 16 x 0.8
Flat copper strip, with holes
max. mm 10 x 16 x 0.8
Cu strip (number of segments x width x segment thickness)
     
Box terminal
     
 
min. mm2 2 x 9 x 0.8
 
max. mm2 10 x 16 x 0.8
Bolt terminal and rear-side connection
     
Flat copper strip, with holes
min. mm 2 x 16 x 0.8
Flat copper strip, with holes
max. mm 10 x 16 x 0.8
Copper busbar (width x thickness)
mm    
Bolt terminal and rear-side connection
     
Screw connection
    M8
Direct on the switch
     
 
min. mm2 16 x 5
 
max. mm2 20 x 5
Control cables
     
 
  mm2 1 x (0.75 - 2.5)
2 x (0.75 - 1.5)
Technical data according to ETIM 4.0
Number of poles
    3
Rated uninterrupted current Iu
  A 250
Number of auxiliary contacts as N/Cs
    0
Number of auxiliary contacts as N/Os
    0
Device construction
    Built-in device fixed built-in technique
With under voltage release
    No
Motor operator optional
    YES
Integrated earth fault protection
    No
Suitable for DIN rail (top hat rail) mounting
    No
Setting range non-delayed short-circuit release
  A 2500
Setting range short-term delayed short-circuit release
  A 0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
  kA 150
Switched-off indicator available
    No
Type of control element
    Toggle lever
Connection type main current circuit
    Screw connection
Motor operator integrated
    No
Position of connection for main circuit
    Front connection
Protection type (IP)
    IP20
Number of auxiliary contacts as changeover contact
    0
Setting range of overload releases
  A 250
Characteristics
Dimensions
Blow out area, minimum clearance to adjacent parts
Minimum clearance to adjacent parts

Opis pochodzi ze strony www.moeller.net .