Wyłącznik mocy 3-bieg.125A zabezp.silnik

  • szt.
  • Discount: -1,684.20 zł (40 %)
  • (Gross discount: -2,071.56 zł (40 %))
  • Gross price: 3,107.34 zł / szt. 2,526.29 zł / szt.

Wyłącznik mocy 3-bieg.125A zabezp.silnika NZMN2-M125

Program
Range
    Circuit-breaker
Protective function
    Motor protection
Standard/Approval
    IEC
Installation type
    Fixed mounted
Release system
    Thermomagnetic release
Construction size
    NZM2
Description
    Tripping class 10 A
IEC/EN 60947-4-1, IEC/EN 60947-2

The circuit-breaker fulfills all requirements for AC-3 switching category.

Number of conductors
    3 pole
Standard equipment
    Screw connection
Switching capacity
     
400/415 V 50/60 Hz
Icu kA 50
Rated current = rated uninterrupted current
In= Iu A 125
Setting range
     
Overload trip
     
Overload releases
Ir A 100- 125
Short-circuit releases
     
Non-delayed
Ii= Inx …   8 - 14
Motor rating AC-3 50/60 Hz
     
400 V
P kW 45
Rated operational current
     
400 V
Ie A 99
 
General
Standards
    IEC/EN 60947
Protection against direct contact
    Finger and back of hand proof to VDE 0106 Part 100
Climatic proofing
    Damp heat, constant to IEC 60068-2-78
Damp heat, cyclic to IEC 60068-2-30
Ambient temperature
  °C  
Ambient temperature, storage
  °C -40- +80
Operation
  °C -25… +70
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27
  g 20 (half-sinusoidal shock 20 ms)
Safe isolation to VDE 0106 Part 101 and Part 101/A1
     
Between auxiliary contacts and main contacts
  V AC 500
between the auxiliary contacts
  V AC 300
Weight
  kg 2.345
Mounting position
     
Mounting position
   
Vertical and 90° in all directions
With residual-current release XFI:
- NZM1, N1, NZM2, N2: vertical and 90° in all directions
with plug-in adapter elements
- NZM1, N1, NZM2, N2: vertical, 90° right/left
with withdrawable unit:
- NZM3, N3: vertical, 90 ° left
- NZM4, N4: vertical
with remote operator:
- NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90° in all directions

 

Direction of incoming supply
    As required
Degree of protection
     
Device
    In the operating controls area: IP20 (basic degree of protection)
Enclosures
    With insulating surround: IP40, with door coupling rotary handle: IP66
Terminations
    Tunnel terminal: IP10
Phase isolator and strip terminal: IP00
Other technical data (sheet catalogue)
    Weight
Temperature dependency, Derating
Effective power loss
Circuit-breakers
Rated current = rated uninterrupted current
In= Iu A 125
Rated surge voltage invariability
Uimp    
Main contacts
  V 8000
Auxiliary contacts
  V 6000
Rated operational voltage
Ue V AC 690
Rated operational voltage
Ue V DC 750
 
   

1) Details apply for 3 pole system protection circuit-breaker with thermomagnetic release NZMN(H)1(2)(3)-A... to 500 A.

For rated operating voltage switching via 3 contacts:

DC correction factor for instantaneous release response value: NZM1: 1.25, NZM2: 1.35, NZM3: 1.45

Set value for Iiat DC = set value IiAC/correction factor DC

Switching of one pole via two series contacts   Switching of one pole via three series contacts
 
Overvoltage category/pollution degree
    III/3
Rated insulation voltage
Ui V 1000
For use in IT electrical power networks
  V 690
Switching capacity
Rated short-circuit making capacity
Icm    
240 V
Icm kA 187
400/415 V
Icm kA 105
440 V 50/60 Hz
Icm kA 74
525 V 50/60 Hz
Icm kA 53
690 V 50/60 H
Ic kA 40
Rated short-circuit breaking capacity Icn
Icn    
Icu to IEC/EN 60947 test cycle O-t-CO
Icu kA  
240 V 50/60 Hz
Icu kA 85
400/415 V 50/60 Hz
Icu kA 50
440 V 50/60 Hz
Icu kA 35
525 V 50/60 Hz
Icu kA 25
690 V 50/60 Hz
Icu kA 20
500 V DC
Icu kA 30
750 V DC
Icu kA 30
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO
Ics kA  
240 V 50/60 Hz
Ics kA 85
400/415 V 50/60 Hz
Ics kA 50
440 V 50/60 Hz
Ics kA 35
525 V 50/60 Hz
Ics kA 25
690 V 50/60 Hz
Ics kA 5
Maximum low-voltage h.b.c. fuse
  A gG/gL 355
 
    Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker.
Rated short-time withstand current
     
t = 0.3 s
Icw kA 1.9
t = 1 s
Icw kA 1.9
Utilization category to IEC/EN 60947-2
    A
Rated making and breaking capacity
     
Rated operational current
Ie A  
AC-1
     
400 V
Ie A 300
415 V
Ie A 300
690 V
Ie A 300
AC--3
     
400 V
Ie A 125
415 V
Ie A 125
690 V
Ie A 125
Lifespan, mechanical(of which max. 50 % trip by shunt/undervoltage release)
Operations   20000
Lifespan, electrical
     
AC-1
     
400 V V 50/60 Hz
Operations   10000
415 V V 50/60 Hz
Operations   10000
690 V 50/60 Hz
Operations   7500
AC--3
     
400 V 50/60 Hz
Operations   6500
415 V 50/60 Hz
Operations   6500
690 V 50/60 Hz
Operations   5000
Max. operating frequency
  Ops/h 120
Current heat losses per pole at Iuare based on the maximum rated operational current of the frame size.
  W 19
 
    For current heat loss per pole the specification refers to the maximum rated operational current of the frame size.
Total downtime in a short-circuit
  ms < 10
Terminal capacity
Standard equipment
    Screw connection
Overview
   
Basic equipment                
  Box terminal     -   -   -
  Screw connection   -      
Accessories                
  Box terminal   -       -
  Screw connection     -   -  
  Tunnel terminal        
  Connection on rear        
  Flat conductor terminal   -   -   -  
Round copper conductor
     
Box terminal
     
Solid
  mm2 1 x (4 - 16)
2 x (4 - 16)
Stranded
  mm2 1 x (25 - 185)
2 x (25 - 70)
Tunnel terminal
     
Solid
  mm2 1 x 16
Stranded
  mm2  
Stranded
  mm2 1 x (25 - 185)
Bolt terminal and rear-side connection
     
Direct on the switch
     
Solid
  mm2 1 x (4 - 16)
2 x (4 - 16)
Stranded
  mm2 1 x (25 - 185)
2 x (25 - 70)
Al conductors, Cu cable
     
 
     
Solid
  mm2 1 x 16
Stranded
  mm2  
Stranded
  mm2 1 x (25 - 185)
je nach Kabelhersteller bis zu 240 mm² anschließbar
Bolt terminal and rear-side connection
     
Flat copper strip, with holes
min. mm 2 x 16 x 0.8
Flat copper strip, with holes
max. mm 10 x 16 x 0.8
Cu strip (number of segments x width x segment thickness)
     
Box terminal
     
 
min. mm2 2 x 9 x 0.8
 
max. mm2 10 x 16 x 0.8
Bolt terminal and rear-side connection
     
Flat copper strip, with holes
min. mm 2 x 16 x 0.8
Flat copper strip, with holes
max. mm 10 x 16 x 0.8
Copper busbar (width x thickness)
mm    
Bolt terminal and rear-side connection
     
Screw connection
    M8
Direct on the switch
     
 
min. mm2 16 x 5
 
max. mm2 20 x 5
Control cables
     
 
  mm2 1 x (0.75 - 2.5)
2 x (0.75 - 1.5)
Technical data according to ETIM 4.0
Rated operation power at AC-3, 400 V
  kWh 55
With integrated auxiliary switch
    No
Rated permanent current Iu
  A 125
With integrated under voltage release
    No
Number of poles
    3
Degree of protection (IP)
    IP20
Connection type main current circuit
    Screw connection
Characteristics
Dimensions
Blow out area, minimum clearance to adjacent parts
Minimum clearance to adjacent parts

Opis pochodzi ze strony www.moeller.net .