Stycznik mocy;AC-3/400V:4kW 3-bieg. DILEM-10(230V50HZ,240V60HZ)

  • pcs.
  • Gross price: 231.86 zł / pcs. 188.50 zł / pcs.
Stycznik mocy;AC-3/400V:4kW 3-bieg. DILEM-10(230V50HZ,240V60HZ)
Program
Product range
  Contactors
Subrange
  DILEM contactors
Application
  Mini Contactors for Motors and Resistive Loads
Description
  With auxiliary contact
Pole
  3 pole
Connection technique
  Screw terminals
Rated operational current
   
AC-3
   
400 V
IeA9
AC-1
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 50 °C
Ith =IeA20
enclosed
IthA16
Max. rating for three-phase motors, 50 - 60 Hz
   
AC-3
   
220 V 230 V
PkW2.2
380 V 400 V
PkW4
660 V 690 V
PkW4
AC-4
   
220 V 230 V
PkW1.5
380 V 400 V
PkW3
660 V 690 V
PkW3
Contacts
   
N/O = Normally open
  1 N/O
Contact sequence
  
For use with
  …DILEM
…DILE
Actuating voltage
  230 V 50Hz, 240 V 60 Hz
Voltage AC/DC
  AC operation
Approbationen
Product StandardsIEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.E29096
UL CCNNLDX
CSA File No.012528
CSA Class No.3211-04
NA CertificationUL Listed, CSA certified
Specially designed for NANo
 
General
Standards
  IEC/EN 60947, VDE 0660, CSA, UL
Lifespan, mechanical; Coil 50/60 Hz
Operationsx 1067
Lifespan, mechanical
Operationsx 10610
Maximum operating frequency
 Ops./h 
Mechanical
 Ops./h9000
Climatic proofing
  Damp heat, constant to IEC 60068-2-78
Damp heat, cyclic to IEC 60068-2-30
Ambient temperature
 °C 
Open
 °C-25- 50
Enclosed
 °C-25- 40
Mounting position
  
As required except vertical with terminals A1/A2 at the bottom
Mounting position
  As required, except vertical with terminals A1/A2 at the bottom
Mechanical shock resistance (IEC/EN 60068-2-27)
   
Half-sinusoidal shock, 10 ms
   
Basic unit without auxiliary contact module
   
Main contacts, make contacts
 g10
Main contacts Make/break contacts
 g10/8
Basic unit with auxiliary contact module
   
Main contacts make contact
 g 
Make
 g10
Auxiliary contacts Make/break contacts
 g20/20
Protection type
  IP20
Protection against direct contact when actuated from front (EN 90274)
  Finger and back-of­hand proof
Weight
 kg0.2
Terminal capacity of auxiliary and main contacts
   
Solid
 mm21 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Flexible with ferrule
 mm21 x (0.75 - 1.5)
2 x (0.75 - 1.5)
Solid or stranded
 AWG18 - 14
Terminal screw
  M3.5
Pozidriv screwdriver
 Size2
Standard screwdriver
 mm0.8 x 5.5
1 x 6
Max. tightening torque
 Nm1.2
Terminal capacity springloaded terminals main and control circuits
   
Solid
 mm21 x (1 - 2.5)
2 x (1 - 2.5)
Flexible with ferrule
 mm21 x (1 - 2.5)
2 x (1 - 2.5)
Standard screwdriver
 mm0.6 x 3.5
Main conducting paths
Rated impulse withstand voltage
UimpV AC6000
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV AC690
Rated operational voltage
UeV AC690
Safe isolation to VDE 0106 Part 101 and Part 101/A1
   
between coil and contacts
 V AC300
between the contacts
 V AC300
Making capacity (cos ϕ to IEC/EN 60947)
 A110
Breaking capacity
   
220/230 V
 A90
380/400 V
 A90
500 V
 A64
660/690 V
 A42
Short-circuit protection maximum fuse
   
Type “2” coordination
gL/gGA 10
Type “1” coordination
gL/gGA 20
AC
AC-1 duty
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA22
at 50 °C
Ith =IeA20
at 55 °C
Ith =IeA19
enclosed
IthA16
Notes
  At maximum permissible ambient air temperature.
Conventional free air thermal current, 1 pole
   
Notes
  At maximum permissible ambient air temperature.
open
IthA50
enclosed
IthA40
AC-3 duty
   
Rated operational current AC-3 open, 50 - 60 Hz, 3 pole
Ie  
Notes
  At maximum permissible ambient air temperature.
220/230 V
IeA9
240 V
IeA9
380/400 V
IeA9
415 V
IeA9
440V
IeA9
500 V
IeA6.4
660/690 V
IeA4.8
Motor rating
PkWh 
220/230 V
PkW2.2
240V
PkW2.5
380/400 V
PkW4
415 V
PkW4.3
440 V
PkW4
500 V
PkW4
660/690 V
PkW4
AC-4 duty
   
Rated operational current AC-4 open, 50 - 60 Hz, 3 pole
Ie  
Notes
  At maximum permissible ambient air temperature.
220/230 V
IeA6.6
240 V
IeA6.6
380/400 V
IeA6.6
415 V
IeA6.6
440 V
IeA6.6
500 V
IeA5
660/690 V
IeA3.4
Motor rating
PkWh 
220/230 V
PkW1.5
240 V
PkW1.8
380/400 V
PkW3
415 V
PkW3.1
440 V
PkW3
500 V
PkW3
660/690 V
PkW3
DC
Rated operational current, open
Ie  
DC - -1
   
12 V
IeA20
24 V
IeA20
60 V
IeA20
110 V
IeA20
220 V
IeA20
DC - 3
   
12 V
IeA8
24 V
IeA8
60 V
IeA4
110 V
IeA3
DC - 5
   
12 V
IeA2.5
24 V
IeA2.5
60 V
IeA2.5
110 V
IeA1.5
220 V
IeA0.3
Current heat losses (3- or 4-pole)
   
to Ith
 W2
at Ieto AC-3/400 V
 W0.5
Magnet systems
Voltage tolerance
 x Uc 
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
Pick-upx Uc0.8- 1.1
Dual-frequency coil 50/60 Hz
Pick-upx Uc0.85- 1.1
Power consumption
   
AC operation
   
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
Pick-upVA25
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
Pick-upW22
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
SealingVA4.6
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
SealingW1.3
Dual-frequency coil 50/60 Hz at 50 Hz
Pick-upVA30
Dual-frequency coil 50/60 Hz at 50 Hz
Pick-upW26
Dual-frequency coil 50/60 Hz at 50 Hz
SealingVA5.4
Dual-frequency coil 50/60 Hz at 50 Hz
SealingW1.6
Dual-frequency coil 50/60 Hz at 60 Hz
Pick-upVA29
Dual-frequency coil 50/60 Hz at 60 Hz
Pick-upW24
Dual-frequency coil 50/60 Hz at 60 Hz
SealingVA3.9
Dual-frequency coil 50/60 Hz at 60 Hz
SealingW1.1
DC operation
   
Notes
  Smoothed DC voltage or three-phase bridge rectifier
Duty factor
 % DF100
Switching times at 100 % Uc
   
Make contact
 ms 
Closing delay
 ms 
Closing delay min.
 ms14
Closing delay max.
 ms21
Opening delay
 ms 
Opening delay min.
 ms8
Opening delay max.
 ms18
Closing delay with top mounting auxiliary contact
 msmax. 45
Reversing contactors
   
Changeover time at 110 % Uc
 ms 
Changeover time min.
 ms16
Changeover time max.
 ms21
Arcing time at 690 V AC
 msmax. 12
Auxiliary contacts
Positive operating contacts to ZH 1/457, including auxiliary contact module
  Yes
Rated impulse withstand voltage
UimpV AC6000
Rated insulation voltage
UiV AC690
Rated operational voltage
UeV 
Rated operational voltage
UeV AC600
Safe isolation to VDE 0106 Part 101 and Part 101/A1
   
between coil and auxiliary contacts
 V AC300
between the auxiliary contacts
 V AC300
Rated operational current
IeA 
AC-15
   
220/240 V
IeA6
380/415 V
IeA3
500 V
IeA1.5
DC-13
   
Contacts in series:
 A 
1
24 VA2.5
2
60 VA2.5
3
100 VA1.5
3
220 VA0.5
Control circuit reliability (at Ue= 24 V DC, Umin= 17 V, I min= 5.4 mA)
Failure rateλ<10-8, < one failure at 100 million operations
Component lifespan at Ue= 240 V
   
AC-15
Operationsx 1060.2
DC-13
   
L/R = 50 ms: 2 contacts in series at Ie= 0.5 A
Operationsx 1060.15
Notes
  Switch-on and switch-off conditions based on DC-13, time constant as specified
Short-circuit rating without welding
   
Maximum overcurrent protective device
   
Short-circuit protection only
  PKZM0-4
Short-circuit protection maximum fuse
   
500 V
 A gG/gL6
500 V
 A fast10
Current heat loss at Ith
   
Per contact
 W0.2
Technical data according to ETIM 4.0
Number of main contacts as N/Os
  3
Rated operation current Ie at AC-1, 400 V
  22
Connection type main circuit
  Screw connection
Rated control voltage Us at AC 60HZ
 V240
Number of auxiliary contacts as N/Os
  1
Rated control voltage Us at AC 50HZ
 V230
Number of auxiliary contacts as N/Cs
  0
Suitable for rail-mounting
  No
Rated control voltage Us at DC
 V0
Voltage type for actuation
  AC
Rated operation current Ie at AC-3, 400 V
 A9
Number of N/Cs as main contact
  0
Motor rating at AC-3, 400 V
 kWh4
Characteristics
1: Overload relay
2: Suppressor
3: Auxiliary contact modules
Enclosure totally insulated
Squirrel-cage motor
Operating characteristics
Starting:from rest
Stopping:after attaining full running speed
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 1 x rated motor current
Utilization category
100 % AC-3
Typical applications
Compressors
Lifts
Mixers
Pumps
Escalators
Agitators
Fans
Conveyor belts
Centrifuges
Hinged flaps
Bucket-elevators
Air conditioning system
General drives in manufacturing and processing machines
Extreme switching duty
Squirrel-cage motor
Operating characteristics
Inching, plugging, reversing
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 6 x rated motor current
Utilization category
100 % AC-4
Typical applications
Printing presses
Wire-drawing machines
Centrifuges
Special drives for manufacturing and processing machines
Switching duty for non-motor loads, 3-pole, 4-pole
Operating characteristics
Non-inductive or slightly inductive loads
Electrical characteristics
Make: 1 x rated current
Break: 1 x rated current
Utilization category
100 % AC-1
Typical applications
Electric heat
Short-time loading, 3-pole
Time interval between two loading cycles: 15 minutes
Dimensions

Opis pochodzi ze strony www.moeller.net .