Stycznik mocy, I=400A (AC-3) 2Z 2R

  • Add feedback:
  • Code: 274196
  • Manufacturer: EATON
  • Availability: Exists  (1 szt.)
  • szt.
  • Discount: -2,475.20 zł (40 %)
  • (Gross discount: -3,044.50 zł (40 %))
  • Gross price: 4,566.74 zł / szt. 3,712.80 zł / szt.
Stycznik mocy, 400 A (200kW), AC-3, 400 V DILM400-S/22(220-240V50/60HZ)
Program
Product range
  Contactors
Application
  Contactors for Motors
Subrange
  Standard devices greater than 150 A
Connection technique
  Screw terminals
Rated operational current
   
AC-3
   
400 V
IeA400
AC-1
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 60 °C
Ith =IeA500
Max. rating for three-phase motors, 50 - 60 Hz
   
AC-3
   
220 V 230 V
PkW125
380 V 400 V
PkW200
660 V 690 V
PkW344
AC-4
   
220 V 230 V
PkW92
380 V 400 V
PkW160
660 V 690 V
PkW283
Contact sequence
  
Can be combined with auxiliary contact
  DILM820-XHI…
Actuating voltage
  220 - 240 V 50/60 Hz
Contacts
   
N/O = Normally open
  2 N/O
N/C = Normally closed
  2 B
Auxiliary contacts
   
possible variants at auxiliary contact module fitting options
  on the side: 2 x DILM820-XHI(V)11-SI; 2 x DILM820-XHI(V)11-SA
Side mounting auxiliary contacts
  
Instructions
  integrated suppressor circuit in actuating electronics
660 V, 690 V or 1000 V: not directly reversing
Notes
DILM…-S contactors are triggered in the conventional manner
Standstill in an emergency (Emergency-Stop)
Approbationen
Product StandardsIEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.E29096
UL CCNNLDX
CSA File No.012528
CSA Class No.3211-04
NA CertificationUL Listed, CSA certified
Specially designed for NANo
 
General
Standards
  IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanical
   
AC operated
Operationsx 1067
DC operated
Operationsx 1067
Operating frequency, mechanical
   
AC operated
Operations/h 2000
DC operated
Operations/h 2000
Climatic proofing
  Damp heat, constant to IEC 60068-2-78
Damp heat, cyclic to IEC 60068-2-30
Ambient temperature
 °C 
Open
 °C-25- 60
Enclosed
 °C-25- 40
Storage
 °C-40- 80
Mounting position
  
Mounting position, AC- and DC operated
  

Mechanical shock resistance (IEC/EN 60068-2-27)
   
Half-sinusoidal shock, 10 ms
   
Main contacts
   
N/O contact
 g10
Auxiliary contacts
   
N/O contact
 g10
N/C contact
 g8
Protection type
  IP00
Protection against direct contact when actuated from front (EN 90274)
  finger and back-of-hand proof with terminal shroud or terminal block
Weight
   
AC operated
 kg8
DC operated
 kg8
Weight
 kg8
Terminal capacity main cable
   
Flexible with cable lug
 mm250 - 240
Stranded with cable lug
 mm270 - 240
Solid or stranded
 AWG2/0 - 500 MCM
Flat conductor
Number of segments x width x thickness mmFixing with flat cable terminal or cable terminal blocks
See terminal capacity for cable terminal blocks
Busbar
Widthmm25
Main cable connection screw/bolt
  M10
Tightening torque
 Nm24
Terminal capacity control circuit cables
   
Solid
 mm21 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Flexible with ferrule
 mm21 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Solid or stranded
 AWG2 x (18 - 12)
Control circuit cable connection screw/bolt
  M3.5
Tightening torque
 Nm1.2
Tool
   
Main cable
   
Open-end spanner
 mm16
Control circuit cables
   
Pozidriv screwdriver
 Size2
Main conducting paths
Rated impulse withstand voltage
UimpV AC8000
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
   
AC
UiV AC1000
Rated operational voltage
UeV AC1000
Safe isolation to VDE 0106 Part 101 and Part 101/A1
   
between coil and contacts
 V AC500
between the contacts
 V AC500
Making capacity (p.f. to IEC/EN 60947)
 A5500
Breaking capacity
   
220/230 V
 A5000
380/400 V
 A5000
500 V
 A5000
660/690 V
 A5000
1000 V
 A950
Short-circuit rating
   
Short-circuit protection maximum fuse
   
Type “2” coordination
   
400 V
gG/gL 500 VA 500
690 V
gG/gL 690 VA 500
1000 V
gG/gL 1000 VA 200
Type “1” coordination
   
400 V
gG/gL 500 VA 630
690 V
gG/gL 690 VA 630
1000 V
gG/gL 1000 VA 250
AC
AC-1 duty
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 40 °C
Ith =IeA612
at 50 °C
Ith =IeA548
at 55 °C
Ith =IeA522
at 60 °C
Ith =IeA500
enclosed
IthA450
Conventional free air thermal current, 1 pole
   
open
IthA1250
enclosed
IthA1125
AC-3 duty
   
Rated operational current AC-3 open, 50 - 60 Hz, 3 pole
Ie  
220/230 V
IeA400
240 V
IeA400
380/400 V
IeA400
415 V
IeA400
440V
IeA400
500 V
IeA400
660/690 V
IeA360
1000 V
IeA95
Motor rating
PkWh 
220/230 V
PkW125
240V
PkW132
380/400 V
PkW200
415 V
PkW240
440 V
PkW200
500 V
PkW290
660/690 V
PkW344
1000 V
PkW132
AC-4 duty
   
Rated operational current AC-4 open, 50 - 60 Hz, 3 pole
Ie  
220/230 V
IeA296
240 V
IeA296
380/400 V
IeA296
415 V
IeA296
440 V
IeA296
500 V
IeA296
660/690 V
IeA296
1000 V
IeA95
Motor rating
PkWh 
220/230 V
PkW92
240 V
PkW101
380/400 V
PkW160
415 V
PkW176
440 V
PkW186
500 V
PkW214
660/690 V
PkW283
1000 V
PkW132
Condensor operation
Individual compensation, rated operational current Ieof three-phase capacitors
   
open
   
up to 525 V
 A307
690 V
 A177
Max. inrush current peak
 x Ie30
Component lifespan
Operationsx 1060.1
Max. operating frequency
 Ops/h200
DC
Rated operational current, open
   
DC-1 operation
   
60 V
IeA400
110 V
IeA400
220 V
IeA400
440 V
IeA11
DC-3 operation
   
60 V
IeA400
110 V
IeA400
220 V
IeA400
DC-5 operation
   
60 V
IeA400
110 V
IeA400
220 V
IeA400
Current heat loss (3 pole)
Current heat loss at Ith
 W58
Current heat loss at Ieto AC-3/400 V
 W37
Magnet systems
Voltage tolerance
 x Uc 
UC
  220 - 240 V 50/60 Hz
AC operated
Pick-upx Uc 
 
Pick-upx Uc0.85 x Uc min- 1.1 x Uc max
Drop-out voltage AC operated
Drop-outx Uc 
 
Drop-outx Uc0.2 x Uc min- 0.4 x Uc max
Power consumption of the coil in a cold state and 1.0 x Uc
   
50 Hz
Pick-upVA450
AC operated
Pick-upW350
60 Hz
Pick-upVA715
60 Hz
Pick-upW645
Dual-frequency coil 50/60 Hz at 50 Hz
SealingVA4.3
Dual-frequency coil 50/60 Hz at 50 Hz
SealingW3.3
Dual-frequency coil 50/60 Hz at 60 Hz
SealingVA4.3
Dual-frequency coil 50/60 Hz at 60 Hz
SealingW3.3
Duty factor
 % DF100
Switching times at 100 % Uc(approximate values)
   
Main contacts
   
AC operated
   
Closing delay
 ms80
Opening delay
 ms110
DC operated
 ms 
Closing delay
 ms55
Opening delay
 ms50
Behaviour in marginal and transitional conditions
   
Sealing
   
Voltage interruptions
   
(0 … 0.2 x Uc min) 10 ms
  Time is bridged successfully
(0 … 0.2 x Uc min) > 10 ms
  Drop-out of the contactor
Voltage drops
   
(0.2 … 0.6 x Uc min) 12 ms
  Time is bridged successfully
(0.2 … 0.6 x Uc min) > 12 ms
  Drop-out of the contactor
(0.6 … 0.7 x Uc min)
  Contactor remains switched on
Excess voltage
   
(1.15 … 1.3 x Uc max)
  Contactor remains switched on
(> 1.3 x Uc max) 3 s
  Contactor remains switched on
(> 1.3 x Uc max) > 3 s
  Drop-out of the contactor
Pick-up phase
   
(0 … 0.7 x Uc min)
  Contactor does not switch on
(0.7 x Uc min … 1.15 x Uc max)
  Contactor switches on with certainty
(> 1.15 x Uc max)
  Contactor switches on with certainty
Admissible transitional contact resistance(of the external control circuit device when actuating A11)
 mΩ500
PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2)
   
High
 V15
Low
 V5
Electromagnetic compatibility (EMC)
Electromagnetic compatibility
  This product is designed for operation in industrial environments (environment 2). The use in residential environments (environment 1) could cause electrical interference so that addition suppression must be planned.
Technical data according to ETIM 4.0
Number of main contacts as N/Os
  3
Rated operation current Ie at AC-1, 400 V
  612
Connection type main circuit
  Screw connection
Rated control voltage Us at AC 60HZ
 V240
Number of auxiliary contacts as N/Os
  2
Rated control voltage Us at AC 50HZ
 V240
Number of auxiliary contacts as N/Cs
  2
Suitable for rail-mounting
  No
Rated control voltage Us at DC
 V0
Voltage type for actuation
  AC
Rated operation current Ie at AC-3, 400 V
 A400
Number of N/Cs as main contact
  0
Motor rating at AC-3, 400 V
 kWh200
Characteristics
on the side: 2 x DILM820-XHI(V)11-SI; 2 x DILM820-XHI(V)11-SA
operating frequency
Squirrel-cage motor
Operating characteristics
Starting:from rest
Stopping:after attaining full running speed
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 1 x rated motor current
Utilization category
100 % AC-3
Typical applications
Compressors
Lifts
Mixers
Pumps
Escalators
Agitators
Fans
Conveyor belts
Centrifuges
Hinged flaps
Bucket-elevators
Air conditioning system
General drives in manufacturing and processing machines
Extreme switching duty
Squirrel-cage motor
Operating characteristics
Inching, plugging, reversing
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 6 x rated motor current
Utilization category
100 % AC-4
Typical applications
Printing presses
Wire-drawing machines
Centrifuges
Special drives for manufacturing and processing machines
Switching duty for non-motor loads, 3-pole, 4-pole
Operating characteristics
Non-inductive or slightly inductive loads
Electrical characteristics
Make: 1 x rated current
Break: 1 x rated current
Utilization category
100 % AC-1
Typical applications
Electric heat
Short-time loading, 3-pole
Time interval between two loading cycles: 15 minutes
Normal switching duty
Dimensions
DILM820-XHI…-SI
DILM820-XHI11-SA

Opis pochodzi ze strony www.moeller.net .