Stycznik pomocniczy DC; 4Z DILER-40-G(24VDC)

  • szt.
  • Cena brutto: 430,25 zł 349,80 zł

Stycznik pomocniczy DC; 4Z DILER-40-G(24VDC)

Program
Product range
    DILER Mini-contactors
Application
    Contactor relays
Connection technique
    Screw terminals
Rated operational current
     
AC-15
     
220 V
230 V
240 V
Ie A 6
380 V
400 V
415 V
Ie A 3
Conv. thermal current
Ith A 10
Contacts
     
N/O = Normally open
    4 N/O
Contact sequence
   
For use with
    …DILE
Actuating voltage
    24 V DC
Voltage AC/DC
    DC operation
Code number and version of combination
     
Distinctive number
    40 E
Auxiliary contact module
Interlocked opposing contacts   40E Conforms to EN 50011 - terminal markings of the coil according to EN 50005
Interlocked opposing contacts 02DILE 42E EN 50011 - Use preferably this combination
Interlocked opposing contacts 04DILE 44E EN 50011 - Use preferably this combination
Interlocked opposing contacts 11DILE 51E EN 50011 - Use preferably this combination
1 early-make contact, 1 late-break contact 11DDILE 51 EN 50005
Interlocked opposing contacts 13DILE 53E EN 50011 - Use preferably this combination
Interlocked opposing contacts 20DILE 60E EN 50011 - Use preferably this combination
Interlocked opposing contacts 22DILE 62E EN 50011 - Use preferably this combination
1 early-make contact, 1 late-break contact 22DDILE 62 EN 50005
Interlocked opposing contacts 31DILE 71E EN 50011 - Use preferably this combination
Interlocked opposing contacts 40DILE 80E EN 50011 - Use preferably this combination
InstructionsContact numbers to EN 50011
Coil terminal markings to EN 50005
Integrated diode-resistor combination
Coil rating 2.6 W
Approbationen
Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No. E29184
UL CCN NKCR
CSA File No. 012528
CSA Class No. 3211-03
NA Certification UL Listed, CSA certified
Specially designed for NA No
 
General
Standards
    IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanical
     
AC operated
Operations x 106 10
DC operated
Operations x 106 20
Maximum operating frequency
  Ops./h  
Maximum operating frequency
Operations/h   9000
Climatic proofing
    Damp heat, constant to IEC 60068-2-78
Damp heat, cyclic to IEC 60068-2-30
Climatic proofing
    Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30
Ambient temperature
  °C  
Open
  °C -25- 50
Enclosed
  °C -25- 40
Mounting position
     
Mounting position
    As required, except vertical with terminals A1/A2 at the bottom
Mechanical shock resistance (IEC/EN 60068-2-27)
     
Half-sinusoidal shock, 10 ms
     
Basic unit with auxiliary contact module
  g  
N/O contact
  g 10
N/C contact
  g 8
Protection type
    IP20
Protection against direct contact when actuated from front (EN 90274)
    Finger and back-of-hand proof
Weight
     
AC operated
  kg 0.17
DC operated
  kg 0.2
Terminal capacities
  mm2  
Screw terminals
     
Solid
  mm2 1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Flexible with ferrule
  mm2 1 x (0.75 - 1.5)
2 x (0.75 - 1.5)
Solid or stranded
  AWG 18 - 14
Terminal screw
    M3.5
Pozidriv screwdriver
  Size 2
Standard screwdriver
  mm 0.8 x 5.5
1 x 6
Max. tightening torque
  Nm 1.2
Spring-loaded terminals
     
Solid
  mm2 1 x (1 - 2.5)
2 x (1 - 2.5)
Flexible with or without ferrule DIN 46228
  mm2 1 x (1 - 2.5)
2 x (1 - 2.5)
Solid or stranded
  AWG 1 x (16 - 14)
2 x (16 - 14)
Standard screwdriver
  mm 0.6 x 3.5
Contacts
Positive operating contacts to ZH 1/457, including auxiliary contact module
    Yes
Rated impulse withstand voltage
Uimp V AC 6000
Overvoltage category/pollution degree
    III/3
Rated insulation voltage
Ui V AC 690
Rated operational voltage
Ue V AC 600
Safe isolation to VDE 0106 Part 101 and Part 101/A1
     
between coil and auxiliary contacts
  V AC 300
between the auxiliary contacts
  V AC 300
Rated operational current
Ie A  
AC-15
     
220/240 V
Ie A 6
380/415 V
Ie A 3
500 V
Ie A 1.5
DC-13
     
DC-13 L/R - 15 ms
     
Contacts in series:
  A  
1
24 V A 2.5
2
60 V A 2.5
3
110 V A 1.5
3
220 V A 0.5
Control circuit reliability (at Ue= 24 V DC, Umin= 17 V, I min= 5.4 mA)
Failure rate λ <10-8, < one failure at 100 million operations
Conv. thermal current
Ith A 10
Short-circuit rating without welding
     
Maximum overcurrent protective device
     
220/240 V
  PKZM0 4
380/415 V
  PKZM0 4
Short-circuit protection maximum fuse
     
500 V
  A gG/gL 6
500 V
  A fast 10
Current heat loss at Ith
     
AC operated
  W 0.2
DC operated
  W 0.3
Magnet systems
Voltage tolerance
  x Uc  
AC operated
  x Uc  
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
Pick-up x Uc 0.8- 1.1
Dual-frequency coil 50/60 Hz
Pick-up x Uc 0.85- 1.1
DC operated
  x Uc  
Pick-up voltage
Pick-up x Uc 0.85- 1.3
at 24 V: without auxiliary contact component (40 °C)
Pick-up x Uc 0.7- 1.3
Power consumption
     
50 Hz
Pick-up VA 25
50 Hz
Sealing VA 4.6
50 Hz
Sealing W 1.3
60 Hz
Pick-up VA 25
60 Hz
Sealing VA 4.6
60 Hz
Sealing W 1.3
50/60 Hz
Pick-up VA 30
29
50/60 Hz
Sealing VA 5.4
3.9
50/60 Hz
Sealing W 1.6
1.1
DC operated
Pull-in = sealing W 2.6
Duty factor
  % DF 100
Switching times at 100 % Uc(approximate values)
     
AC operated closing delay
  ms 14- 21
AC operated N/O contact opening delay
  ms 8- 18
AC operated With auxiliary contact module Max. closing delay
  ms 45
DC operated closing delay
  ms 26- 35
DC operated N/O contact opening delay
  ms 15- 25
DC operated With auxiliary contact module Max. closing delay
  ms 70
Notes
Notes Making and breaking conditions to DC-13, time constant as stated
See transparent overlay "Fuses" for time/current characteristics (please enquire)
Use only equal cross-sections
Technical data according to ETIM 4.0
Connection type main circuit
    Screw connection
Rated control voltage Us at DC
  V 24
Rated control voltage Us at AC 60HZ
  V 0
Rated control voltage Us at AC 50HZ
  V 0
Number of auxiliary contacts as changeover contacts
    0
Rated operation current Ie , 400 V
  A 3
Number of auxiliary contacts as N/Cs
    0
Number of auxiliary contacts as N/Os
    4
Voltage type for actuation
    DC
Number of auxiliary contacts as N/Os, leading
    0
Number of auxiliary contacts as N/Cs, delayed switching
    0
Characteristics
1: Suppressor
2: Auxiliary contact module
Component lifespan (operations)
Ie = Rated operational current
Dimensions
DILER-…
DILER-…-G
DILER-… + …DILE
DILER-…-G + …DILE

Opis pochodzi ze strony www.moeller.net .