DILA-XHI22 - styki pomocnicze 2Z 2R

  • szt.
  • Rabat: -34,07 zł (40 %)
  • (Rabat brutto: -41,90 zł (40 %))
  • Cena brutto: 62,86 zł / szt. 51,11 zł / szt.
Moduł styków pomocnicznych DILA-XHI22
Program
Product range
  Accessories
Accessories
  Auxiliary contact modules
Description
  with interlocked opposing contacts
Function
  for standard applications
Connection technique
  Screw terminals
Pole
  4 pole
Contacts
   
N/O = Normally open
  2 N/O
N/C = Normally closed
  2 N/C
Contact sequence
  
Can be combined with basic unit
  DILM(C)7…
DILM(C)9…
DILM(C)12…
DILM(C)15…
DILM(C)17…
DILM(C)25…
DILM(C)32…
DILM38…
DILMP20…
DILMP32…
DILMP45…
DILL…
AC-15
   
AC-15
   
220 V 230 V 240 V
IeA4
380 V 400V 415 V
IeA4
Rated operational current
   
AC-1
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 60 °C
Ith =IeA16
Instructions
  Interlocked opposing contacts according to IEC/EN 60947-5-1 appendix L, inside the auxiliary contact modules, also for the integrated auxiliary contacts of the DILM 7 - DILM32
Auxiliary contacts used as mirror contacts according to IEC/EN 60947-4-1 Appendix F (not N/C late open)
Code number and version of combination
   
DILA(C)-40
  62E
DILA(C)-31
  53
DILA(C)-22
  44
Approbationen
Product StandardsIEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.E29184
UL CCNNKCR
CSA File No.012528
CSA Class No.3211-03
NA CertificationUL Listed, CSA certified
Specially designed for NANo
 
Auxiliary contacts
Interlocked opposing contacts within an auxiliary contact module (to IEC 60947-5-1 Annex L)
  Yes
N/C contact (not late-break contact) suitable as a mirror contact (to IEC/EN 60947-4-1 Annex F)
  DILM7 - DILM32
Rated impulse withstand voltage
UimpV AC6000
Overvoltage category/pollution degree
  III/3
Rated insulation voltage
UiV AC690
Rated operational voltage
UeV AC500
Safe isolation to VDE 0106 Part 101 and Part 101/A1
   
between coil and auxiliary contacts
 V AC400
between the auxiliary contacts
 V AC400
Rated operational current
IeA 
AC-15
   
230 V
IeA4
380/415 V
IeA4
500 V
IeA1.5
DC L/R 15 ms
   
24 V
IeA10
60 V
IeA6
110 V
IeA3
220 V
IeA1
Rated operational current
   
Conventional free air thermal current, 3 pole, 50 - 60 Hz
   
Open
   
at 60 °C
Ith =IeA16
Control circuit reliability (at Ue= 24 V DC, Umin= 17 V, I min= 5.4 mA)
Failure rateλ<10-8, < 1 one failure at 100 million operations
Component lifespan
   
at Ue= 230 V, AC-15, 3 A
Operationsx 1061.3
Short-circuit rating without welding
   
max. fuse
 A gG/gL10
Technical data according to ETIM 4.0
Suitable for earth leakage circuit breaker
  No
Type of electric connection
  Screw connection
Rated operation current Ie at AC-15, 230 V
 A4
Mounting type
  Front mount
Suitable for pendant switch
  No
Suitable for front element
  No
Suitable for circuit-breakers
  No
Suitable for safety position switches
  No
Suitable for step switches
  No
Suitable for pressure switch/selector switch actuator
  No
Suitable for cam switches
  No
Suitable for motor protective circuit breakers
  No
Suitable for series-mounting relays
  No
Suitable for solenoid
  No
Suitable for compact switch-disconnector
  No
Suitable for miniature circuit-breakers
  No
Suitable for pulse relay
  No
Suitable for contactor relay relay
  YES
Suitable for pendant pushbutton
  No
Suitable for residual current device
  No
Number of contacts as change-over contact
  0
Number of contacts as N/O
  2
Number of contacts as NC
  2
Suitable for impulse relays
  No
Suitable for position switches
  No
Suitable for switch-disconnector/residual current device
  No
Suitable for contactors
  YES
Suitable for installation contactor / installation relay
  No
Dimensions
Contactor with auxiliary contact module

Opis pochodzi ze strony www.moeller.net .