Układ rozruchu bezpośredniego

  • szt.
  • Discount: -759.20 zł (40 %)
  • (Gross discount: -933.82 zł (40 %))
  • Gross price: 1,400.72 zł / szt. 1,138.80 zł / szt.
Układ rozruchu, bezpośredniego MSC-D-32-M32(24VDC)
Program
Product range
  MSC Motor-starter combinations
Basic function
  DOL starters (complete units)
Basic device
  Motor starter combinations MSC
Motor ratings
   
Motor rating
   
AC-3
   
DILM contactors
PkW15
Rated operational current 400 V
IeA29.3
Rated short-circuit current 380 - 415 V
IqkA50
Setting range
   
Setting range of overload releases
IrA25 - 32
Non-delayed
IrmA448
Coordination
  Type of coordination “1”
Type of coordination “2”
Contact sequence
  
Actuating voltage
  24 V DC
 
  DC voltage
Motor-protective circuit-breakersPKZM0-32
ContactorDILM32-10(...)
DOL starter wiring set



Mechanical connection element and electrical electric contact modulePKZM0-XDM32
Notes

The DOL starter (complete device) consists of a PKZM0 motor protective circuit breaker and a DILM contactor.

With the adapter-less top-hat rail mounting of starters up to 15 A, only the motor protective circuit breaker on the top-hat rail requires an adapter. The contactors are provided with mechanical support via a mechanical connection element.

Control wire guide with max. 6 conductors up to 2.5°mm external diameter or 4 conductors up to 3.5°mm external diameter.

From 16 A, the motor protective circuit breaker and contactor are mounted on the top hat rail adapter plate.

The connection of the main circuit between PKZ and contactor is established with electrical contact modules.

When using the auxiliary contacts DILA‐XHIT… (→ 101042) the plug-in electrical connector can be removed without the removal of the front mounting auxiliary contact.

Notes

BK25/3-PKZ0-E extension terminal and if necessary B3.../...-PKZ0 three-phase commoning link can be added to motor-starter combinations to make Type F starters in accordance with UL508.

 
General
Standards
  
UL 508 (on request)
CSA C 22.2 No. 14 (on request)
Mounting position
  
Main conducting paths
Rated impulse withstand voltage
UimpV AC6000
Overvoltage category/pollution degree
  III/3
Rated operational voltage
UeV230- 415
Additional technical data
Motor protective circuit breaker PKZM0, PKE
  PKZM0 motor-protective circuit-breakers, see motor-protective circuit-breakers/PKZM0 product group
DILM contactors, see contactors product group
DILET timing relay, ETR, see contactors, electronic timing relays product group
Technical data according to ETIM 4.0
Connection type main circuit
  Screw connection
Protection type (IP)
  IP00
Rated control voltage Us at AC 60HZ
 V0
Function
  DOL starter
Setting range of overload releases
 A32
Type of coordination
  1.2
Motor rating at AC-3, 400 V
 kWh15
Voltage type for actuation
  DC
Rated operational current Ie
 A29.3
Rated control voltage Us at DC
 V24
Rated conditional short-circuit current Iq
 kA50
With short-circuit release
  YES
Bus-capable
  YES
Rated control voltage Us at AC 50HZ
 V0
Dimensions
MSC-D-…-M17[…32]…

Opis pochodzi ze strony www.moeller.net .