DILM250/22(RA250) - Stycznik mocy I=250A [AC-3] 2Z 2R
- szt.
- Discount: -2,031.20 zł (40 %)
- (Gross discount: -2,498.38 zł (40 %))
- Gross price: 3,747.56 zł / szt. 3,046.80 zł / szt.
Stycznik mocy z modułem 2Z2R 132kW/400V/AC3 DILM250/22(RA250)
Program
Approbationen
|
General | |||
Standards
|
IEC/EN 60947, VDE 0660, UL, CSA | ||
Lifespan, mechanical
|
|||
AC operated
|
Operations | x 106 | 10 |
DC operated
|
Operations | x 106 | 10 |
Operating frequency, mechanical
|
|||
AC operated
|
Operations/h | 3000 | |
DC operated
|
Operations/h | 3000 | |
Climatic proofing
|
Damp heat, constant to IEC 60068-2-78 Damp heat, cyclic to IEC 60068-2-30 |
||
Ambient temperature
|
°C | ||
Open
|
°C | -25- 60 | |
Enclosed
|
°C | -25- 40 | |
Storage
|
°C | -40- 80 | |
Mounting position
|
|||
Mounting position, AC- and DC operated
|
|||
Mechanical shock resistance (IEC/EN 60068-2-27)
|
|||
Half-sinusoidal shock, 10 ms
|
|||
Main contacts
|
|||
N/O contact
|
g | 10 | |
Auxiliary contacts
|
|||
N/O contact
|
g | 10 | |
N/C contact
|
g | 8 | |
Protection type
|
IP00 | ||
Protection against direct contact when actuated from front (EN 90274)
|
finger and back-of-hand proof with terminal shroud or terminal block | ||
Weight
|
|||
AC operated
|
kg | 6.5 | |
DC operated
|
kg | 6.5 | |
Weight
|
kg | 6.5 | |
Terminal capacity main cable
|
|||
Flexible with cable lug
|
mm2 | 50 - 240 | |
Stranded with cable lug
|
mm2 | 70 - 240 | |
Solid or stranded
|
AWG | 2/0 - 500 MCM | |
Flat conductor
|
Number of segments x width x thickness | mm | Fixing with flat cable terminal or cable terminal blocks See terminal capacity for cable terminal blocks |
Busbar
|
Width | mm | 25 |
Main cable connection screw/bolt
|
M10 | ||
Tightening torque
|
Nm | 24 | |
Terminal capacity control circuit cables
|
|||
Solid
|
mm2 | 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) |
|
Flexible with ferrule
|
mm2 | 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) |
|
Solid or stranded
|
AWG | 2 x (18 - 12) | |
Control circuit cable connection screw/bolt
|
M3.5 | ||
Tightening torque
|
Nm | 1.2 | |
Tool
|
|||
Main cable
|
|||
Open-end spanner
|
mm | 16 | |
Control circuit cables
|
|||
Pozidriv screwdriver
|
Size | 2 | |
Main conducting paths | |||
Rated impulse withstand voltage
|
Uimp | V AC | 8000 |
Overvoltage category/pollution degree
|
III/3 | ||
Rated insulation voltage
|
|||
AC
|
Ui | V AC | 1000 |
Rated operational voltage
|
Ue | V AC | 1000 |
Safe isolation to VDE 0106 Part 101 and Part 101/A1
|
|||
between coil and contacts
|
V AC | 500 | |
between the contacts
|
V AC | 500 | |
Making capacity (p.f. to IEC/EN 60947)
|
A | 3000 | |
Breaking capacity
|
|||
220/230 V
|
A | 2500 | |
380/400 V
|
A | 2500 | |
500 V
|
A | 2500 | |
660/690 V
|
A | 2500 | |
1000 V
|
A | 760 | |
Short-circuit rating
|
|||
Short-circuit protection maximum fuse
|
|||
Type “2” coordination
|
|||
400 V
|
gG/gL 500 V | A | 315 |
690 V
|
gG/gL 690 V | A | 315 |
1000 V
|
gG/gL 1000 V | A | 160 |
Type “1” coordination
|
|||
400 V
|
gG/gL 500 V | A | 400 |
690 V
|
gG/gL 690 V | A | 400 |
1000 V
|
gG/gL 1000 V | A | 200 |
AC | |||
AC-1 duty
|
|||
Conventional free air thermal current, 3 pole, 50 - 60 Hz
|
|||
Open
|
|||
at 40 °C
|
Ith =Ie | A | 400 |
at 50 °C
|
Ith =Ie | A | 360 |
at 55 °C
|
Ith =Ie | A | 340 |
at 60 °C
|
Ith =Ie | A | 330 |
enclosed
|
Ith | A | 300 |
Conventional free air thermal current, 1 pole
|
|||
open
|
Ith | A | 825 |
enclosed
|
Ith | A | 742 |
AC-3 duty
|
|||
Rated operational current AC-3 open, 50 - 60 Hz, 3 pole
|
Ie | ||
220/230 V
|
Ie | A | 250 |
240 V
|
Ie | A | 250 |
380/400 V
|
Ie | A | 250 |
415 V
|
Ie | A | 250 |
440V
|
Ie | A | 250 |
500 V
|
Ie | A | 250 |
660/690 V
|
Ie | A | 250 |
1000 V
|
Ie | A | 76 |
Motor rating
|
P | kWh | |
220/230 V
|
P | kW | 75 |
240V
|
P | kW | 85 |
380/400 V
|
P | kW | 132 |
415 V
|
P | kW | 148 |
440 V
|
P | kW | 132 |
500 V
|
P | kW | 180 |
660/690 V
|
P | kW | 240 |
1000 V
|
P | kW | 108 |
AC-4 duty
|
|||
Rated operational current AC-4 open, 50 - 60 Hz, 3 pole
|
Ie | ||
220/230 V
|
Ie | A | 200 |
240 V
|
Ie | A | 200 |
380/400 V
|
Ie | A | 200 |
415 V
|
Ie | A | 200 |
440 V
|
Ie | A | 200 |
500 V
|
Ie | A | 200 |
660/690 V
|
Ie | A | 200 |
1000 V
|
Ie | A | 76 |
Motor rating
|
P | kWh | |
220/230 V
|
P | kW | 62 |
240 V
|
P | kW | 68 |
380/400 V
|
P | kW | 110 |
415 V
|
P | kW | 117 |
440 V
|
P | kW | 125 |
500 V
|
P | kW | 143 |
660/690 V
|
P | kW | 189 |
1000 V
|
P | kW | 108 |
Condensor operation | |||
Individual compensation, rated operational current Ieof three-phase capacitors
|
|||
open
|
|||
up to 525 V
|
A | 220 | |
690 V
|
A | 133 | |
Max. inrush current peak
|
x Ie | 30 | |
Component lifespan
|
Operations | x 106 | 0.1 |
Max. operating frequency
|
Ops/h | 200 | |
DC | |||
Rated operational current, open
|
|||
DC-1 operation
|
|||
60 V
|
Ie | A | 300 |
110 V
|
Ie | A | 300 |
220 V
|
Ie | A | 300 |
440 V
|
Ie | A | 11 |
DC-3 operation
|
|||
60 V
|
Ie | A | 300 |
110 V
|
Ie | A | 300 |
220 V
|
Ie | A | 300 |
DC-5 operation
|
|||
60 V
|
Ie | A | 300 |
110 V
|
Ie | A | 300 |
220 V
|
Ie | A | 300 |
Current heat loss (3 pole) | |||
Current heat loss at Ith
|
W | 55 | |
Current heat loss at Ieto AC-3/400 V
|
W | 28 | |
Magnet systems | |||
Voltage tolerance
|
x Uc | ||
UC
|
110 - 250 V 40-60 Hz 110 - 250 V DC |
||
AC operated
|
Pick-up | x Uc | |
|
Pick-up | x Uc | 0.7 x Uc min- 1.15 x Uc max |
DC operated
|
Pick-up | x Uc | |
|
Pick-up | x Uc | 0.7 x Uc min- 1.15 x Uc max |
Drop-out voltage AC operated
|
Drop-out | x Uc | |
|
Drop-out | x Uc | 0.2 x Uc min- 0.6 x Uc max |
DC operated
|
Drop-out | x Uc | |
|
Drop-out | x Uc | 0.2 x Uc min- 0.6 x Uc max |
Power consumption of the coil in a cold state and 1.0 x Uc
|
|||
50 Hz
|
Pick-up | VA | 380 |
AC operated
|
Pick-up | W | 250 |
60 Hz
|
Pick-up | VA | 360 |
60 Hz
|
Pick-up | W | 325 |
Dual-frequency coil 50/60 Hz at 50 Hz
|
Sealing | VA | 4.3 |
Dual-frequency coil 50/60 Hz at 50 Hz
|
Sealing | W | 3.3 |
Dual-frequency coil 50/60 Hz at 60 Hz
|
Sealing | VA | 4.3 |
Dual-frequency coil 50/60 Hz at 60 Hz
|
Sealing | W | 3.3 |
Duty factor
|
% DF | 100 | |
Switching times at 100 % Uc(approximate values)
|
|||
Main contacts
|
|||
AC operated
|
|||
Closing delay
|
ms | 100 | |
Opening delay
|
ms | 110 | |
DC operated
|
ms | ||
Closing delay
|
ms | 55 | |
Opening delay
|
ms | 40 | |
Behaviour in marginal and transitional conditions
|
|||
Sealing
|
|||
Voltage interruptions
|
|||
(0 … 0.2 x Uc min) 10 ms
|
Time is bridged successfully | ||
(0 … 0.2 x Uc min) > 10 ms
|
Drop-out of the contactor | ||
Voltage drops
|
|||
(0.2 … 0.6 x Uc min) 12 ms
|
Time is bridged successfully | ||
(0.2 … 0.6 x Uc min) > 12 ms
|
Drop-out of the contactor | ||
(0.6 … 0.7 x Uc min)
|
Contactor remains switched on | ||
Excess voltage
|
|||
(1.15 … 1.3 x Uc max)
|
Contactor remains switched on | ||
(> 1.3 x Uc max) 3 s
|
Contactor remains switched on | ||
(> 1.3 x Uc max) > 3 s
|
Drop-out of the contactor | ||
Pick-up phase
|
|||
(0 … 0.7 x Uc min)
|
Contactor does not switch on | ||
(0.7 x Uc min … 1.15 x Uc max)
|
Contactor switches on with certainty | ||
(> 1.15 x Uc max)
|
Contactor switches on with certainty | ||
Admissible transitional contact resistance(of the external control circuit device when actuating A11)
|
mΩ | 500 | |
PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2)
|
|||
High
|
V | 15 | |
Low
|
V | 5 | |
Electromagnetic compatibility (EMC) | |||
Electromagnetic compatibility
|
This product is designed for operation in industrial environments (environment 2). The use in residential environments (environment 1) could cause electrical interference so that addition suppression must be planned. |
Technical data according to ETIM 4.0
Number of main contacts as N/Os
|
3 | ||
Rated operation current Ie at AC-1, 400 V
|
429 | ||
Connection type main circuit
|
Screw connection | ||
Rated control voltage Us at AC 60HZ
|
V | 250 | |
Number of auxiliary contacts as N/Os
|
2 | ||
Rated control voltage Us at AC 50HZ
|
V | 250 | |
Number of auxiliary contacts as N/Cs
|
2 | ||
Suitable for rail-mounting
|
No | ||
Rated control voltage Us at DC
|
V | 250 | |
Voltage type for actuation
|
AC/DC | ||
Rated operation current Ie at AC-3, 400 V
|
A | 250 | |
Number of N/Cs as main contact
|
0 | ||
Motor rating at AC-3, 400 V
|
kWh | 132 |
Characteristics
on the side: 2 x DILM820-XHI(V)11-SI; 2 x DILM820-XHI(V)11-SA | |||
→ operating frequency | |||
Squirrel-cage motor Operating characteristics Starting:from rest Stopping:after attaining full running speed Electrical characteristics Make: up to 6 x rated motor current Break: up to 1 x rated motor current Utilization category 100 % AC-3 Typical applications Compressors Lifts Mixers Pumps Escalators Agitators Fans Conveyor belts Centrifuges Hinged flaps Bucket-elevators Air conditioning system General drives in manufacturing and processing machines |
|||
Extreme switching duty Squirrel-cage motor Operating characteristics Inching, plugging, reversing Electrical characteristics Make: up to 6 x rated motor current Break: up to 6 x rated motor current Utilization category 100 % AC-4 Typical applications Printing presses Wire-drawing machines Centrifuges Special drives for manufacturing and processing machines |
|||
Switching duty for non-motor loads, 3-pole, 4-pole Operating characteristics Non-inductive or slightly inductive loads Electrical characteristics Make: 1 x rated current Break: 1 x rated current Utilization category 100 % AC-1 Typical applications Electric heat |
|||
Short-time loading, 3-pole Time interval between two loading cycles: 15 minutes |
|||
Normal switching duty |
CAD-Data
|
Additional product information (links)
IL03406002Z (AWA2100-1639) contactors | |||
Installation Instructions | |||
Documentation | |||
Motor starters and "Special Purpose Ratings" for the North American market | |||
Busbar Component Adapters for modern Industrial control panels | |||
The Interaction of Contactors with PLCs | |||
Standard Compliant and Functionally Safe Engineering Design with Mechanical Auxiliary Contacts | |||
Switchgear for Luminaires | |||
Effect of the Cabel Capacitance of Long Control Cables on the Actuation of Contactors | |||
X-Start - Modern Switching Installations Efficiently Fitted and Wired Securely | |||
Mirror Contacts for Highly-Reliable Information Relating to Safety-Related Control Functions | |||
X-Start - New Generation:100 years of Moeler contactors - Continous Progress- | |||
Switchgear of Power Factor Correction Systems |
Opis pochodzi ze strony www.moeller.net .