DILM250/22(RA250) - Stycznik mocy I=250A [AC-3] 2Z 2R

  • szt.
  • Discount: -2,031.20 zł (40 %)
  • (Gross discount: -2,498.38 zł (40 %))
  • Gross price: 3,747.56 zł / szt. 3,046.80 zł / szt.

Stycznik mocy z modułem 2Z2R 132kW/400V/AC3 DILM250/22(RA250)

Program
Product range
    Contactors
Application
    Contactors for Motors
Subrange
    Comfort devices greater than 150 A
Connection technique
    Screw terminals
Rated operational current
     
AC-3
     
380 V 400 V
Ie A 250
AC-1
     
Conventional free air thermal current, 3 pole, 50 - 60 Hz
     
Open
     
at 60 °C
Ith =Ie A 330
Max. rating for three-phase motors, 50 - 60 Hz
     
AC-3
     
220 V 230 V
P kW 75
380 V 400 V
P kW 132
660 V 690 V
P kW 240
1000 V
P kW 108
AC-4
     
220 V 230 V
P kW 62
380 V 400 V
P kW 110
660 V 690 V
P kW 189
1000 V
P kW 108
Contact sequence
   
Actuating voltage
    RA 250: 110-250 V 40-60 Hz/110-250 V DC
Auxiliary contacts
     
possible variants at auxiliary contact module fitting options
    on the side: 2 x DILM820-XHI(V)11-SI; 2 x DILM820-XHI(V)11-SA
Side mounting auxiliary contacts
   
Instructions
    integrated suppressor circuit in actuating electronics
660 V, 690 V or 1000 V: not directly reversing
Note concerning the product
Classical   DILM250 to DILM1000, DILH1400
A1/A2 are attached to power supply as normal  
Direct from the PLC    
A 3 V output from the PLC can be directly connected to the connections A4/A24.  
From a low-power actuating device
Low-power actuating devices such as PCB relays, actuating devices or position switches can be directly connected to A10/A11.  
   

Stopping in the event of an emergency (emergency switching off)

Max. capacity 6 nF

Notes
When operating contactors DILM580 to DILM1600 with frequency inverter, the suppressor circuit on the load side must be removed.
During a high voltage test for the contactors DILM580 to DILH2600 the suppressor circuit on the load side must be removed.
Control voltages    
RA250 110 V - 250 V AC/DC    
RAW250 230 V - 250 V AC/DC    
     
Approbationen
Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No. E29096
UL CCN NLDX
CSA File No. 1017510
CSA Class No. 3211-04
NA Certification UL Listed, CSA certified
Specially designed for NA No
 
General
Standards
    IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanical
     
AC operated
Operations x 106 10
DC operated
Operations x 106 10
Operating frequency, mechanical
     
AC operated
Operations/h   3000
DC operated
Operations/h   3000
Climatic proofing
    Damp heat, constant to IEC 60068-2-78
Damp heat, cyclic to IEC 60068-2-30
Ambient temperature
  °C  
Open
  °C -25- 60
Enclosed
  °C -25- 40
Storage
  °C -40- 80
Mounting position
   
Mounting position, AC- and DC operated
   

Mechanical shock resistance (IEC/EN 60068-2-27)
     
Half-sinusoidal shock, 10 ms
     
Main contacts
     
N/O contact
  g 10
Auxiliary contacts
     
N/O contact
  g 10
N/C contact
  g 8
Protection type
    IP00
Protection against direct contact when actuated from front (EN 90274)
    finger and back-of-hand proof with terminal shroud or terminal block
Weight
     
AC operated
  kg 6.5
DC operated
  kg 6.5
Weight
  kg 6.5
Terminal capacity main cable
     
Flexible with cable lug
  mm2 50 - 240
Stranded with cable lug
  mm2 70 - 240
Solid or stranded
  AWG 2/0 - 500 MCM
Flat conductor
Number of segments x width x thickness mm Fixing with flat cable terminal or cable terminal blocks
See terminal capacity for cable terminal blocks
Busbar
Width mm 25
Main cable connection screw/bolt
    M10
Tightening torque
  Nm 24
Terminal capacity control circuit cables
     
Solid
  mm2 1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Flexible with ferrule
  mm2 1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Solid or stranded
  AWG 2 x (18 - 12)
Control circuit cable connection screw/bolt
    M3.5
Tightening torque
  Nm 1.2
Tool
     
Main cable
     
Open-end spanner
  mm 16
Control circuit cables
     
Pozidriv screwdriver
  Size 2
Main conducting paths
Rated impulse withstand voltage
Uimp V AC 8000
Overvoltage category/pollution degree
    III/3
Rated insulation voltage
     
AC
Ui V AC 1000
Rated operational voltage
Ue V AC 1000
Safe isolation to VDE 0106 Part 101 and Part 101/A1
     
between coil and contacts
  V AC 500
between the contacts
  V AC 500
Making capacity (p.f. to IEC/EN 60947)
  A 3000
Breaking capacity
     
220/230 V
  A 2500
380/400 V
  A 2500
500 V
  A 2500
660/690 V
  A 2500
1000 V
  A 760
Short-circuit rating
     
Short-circuit protection maximum fuse
     
Type “2” coordination
     
400 V
gG/gL 500 V A 315
690 V
gG/gL 690 V A 315
1000 V
gG/gL 1000 V A 160
Type “1” coordination
     
400 V
gG/gL 500 V A 400
690 V
gG/gL 690 V A 400
1000 V
gG/gL 1000 V A 200
AC
AC-1 duty
     
Conventional free air thermal current, 3 pole, 50 - 60 Hz
     
Open
     
at 40 °C
Ith =Ie A 400
at 50 °C
Ith =Ie A 360
at 55 °C
Ith =Ie A 340
at 60 °C
Ith =Ie A 330
enclosed
Ith A 300
Conventional free air thermal current, 1 pole
     
open
Ith A 825
enclosed
Ith A 742
AC-3 duty
     
Rated operational current AC-3 open, 50 - 60 Hz, 3 pole
Ie    
220/230 V
Ie A 250
240 V
Ie A 250
380/400 V
Ie A 250
415 V
Ie A 250
440V
Ie A 250
500 V
Ie A 250
660/690 V
Ie A 250
1000 V
Ie A 76
Motor rating
P kWh  
220/230 V
P kW 75
240V
P kW 85
380/400 V
P kW 132
415 V
P kW 148
440 V
P kW 132
500 V
P kW 180
660/690 V
P kW 240
1000 V
P kW 108
AC-4 duty
     
Rated operational current AC-4 open, 50 - 60 Hz, 3 pole
Ie    
220/230 V
Ie A 200
240 V
Ie A 200
380/400 V
Ie A 200
415 V
Ie A 200
440 V
Ie A 200
500 V
Ie A 200
660/690 V
Ie A 200
1000 V
Ie A 76
Motor rating
P kWh  
220/230 V
P kW 62
240 V
P kW 68
380/400 V
P kW 110
415 V
P kW 117
440 V
P kW 125
500 V
P kW 143
660/690 V
P kW 189
1000 V
P kW 108
Condensor operation
Individual compensation, rated operational current Ieof three-phase capacitors
     
open
     
up to 525 V
  A 220
690 V
  A 133
Max. inrush current peak
  x Ie 30
Component lifespan
Operations x 106 0.1
Max. operating frequency
  Ops/h 200
DC
Rated operational current, open
     
DC-1 operation
     
60 V
Ie A 300
110 V
Ie A 300
220 V
Ie A 300
440 V
Ie A 11
DC-3 operation
     
60 V
Ie A 300
110 V
Ie A 300
220 V
Ie A 300
DC-5 operation
     
60 V
Ie A 300
110 V
Ie A 300
220 V
Ie A 300
Current heat loss (3 pole)
Current heat loss at Ith
  W 55
Current heat loss at Ieto AC-3/400 V
  W 28
Magnet systems
Voltage tolerance
  x Uc  
UC
    110 - 250 V 40-60 Hz
110 - 250 V DC
AC operated
Pick-up x Uc  
 
Pick-up x Uc 0.7 x Uc min- 1.15 x Uc max
DC operated
Pick-up x Uc  
 
Pick-up x Uc 0.7 x Uc min- 1.15 x Uc max
Drop-out voltage AC operated
Drop-out x Uc  
 
Drop-out x Uc 0.2 x Uc min- 0.6 x Uc max
DC operated
Drop-out x Uc  
 
Drop-out x Uc 0.2 x Uc min- 0.6 x Uc max
Power consumption of the coil in a cold state and 1.0 x Uc
     
50 Hz
Pick-up VA 380
AC operated
Pick-up W 250
60 Hz
Pick-up VA 360
60 Hz
Pick-up W 325
Dual-frequency coil 50/60 Hz at 50 Hz
Sealing VA 4.3
Dual-frequency coil 50/60 Hz at 50 Hz
Sealing W 3.3
Dual-frequency coil 50/60 Hz at 60 Hz
Sealing VA 4.3
Dual-frequency coil 50/60 Hz at 60 Hz
Sealing W 3.3
Duty factor
  % DF 100
Switching times at 100 % Uc(approximate values)
     
Main contacts
     
AC operated
     
Closing delay
  ms 100
Opening delay
  ms 110
DC operated
  ms  
Closing delay
  ms 55
Opening delay
  ms 40
Behaviour in marginal and transitional conditions
     
Sealing
     
Voltage interruptions
     
(0 … 0.2 x Uc min) 10 ms
    Time is bridged successfully
(0 … 0.2 x Uc min) > 10 ms
    Drop-out of the contactor
Voltage drops
     
(0.2 … 0.6 x Uc min) 12 ms
    Time is bridged successfully
(0.2 … 0.6 x Uc min) > 12 ms
    Drop-out of the contactor
(0.6 … 0.7 x Uc min)
    Contactor remains switched on
Excess voltage
     
(1.15 … 1.3 x Uc max)
    Contactor remains switched on
(> 1.3 x Uc max) 3 s
    Contactor remains switched on
(> 1.3 x Uc max) > 3 s
    Drop-out of the contactor
Pick-up phase
     
(0 … 0.7 x Uc min)
    Contactor does not switch on
(0.7 x Uc min … 1.15 x Uc max)
    Contactor switches on with certainty
(> 1.15 x Uc max)
    Contactor switches on with certainty
Admissible transitional contact resistance(of the external control circuit device when actuating A11)
  mΩ 500
PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2)
     
High
  V 15
Low
  V 5
Electromagnetic compatibility (EMC)
Electromagnetic compatibility
    This product is designed for operation in industrial environments (environment 2). The use in residential environments (environment 1) could cause electrical interference so that addition suppression must be planned.
Technical data according to ETIM 4.0
Number of main contacts as N/Os
    3
Rated operation current Ie at AC-1, 400 V
    429
Connection type main circuit
    Screw connection
Rated control voltage Us at AC 60HZ
  V 250
Number of auxiliary contacts as N/Os
    2
Rated control voltage Us at AC 50HZ
  V 250
Number of auxiliary contacts as N/Cs
    2
Suitable for rail-mounting
    No
Rated control voltage Us at DC
  V 250
Voltage type for actuation
    AC/DC
Rated operation current Ie at AC-3, 400 V
  A 250
Number of N/Cs as main contact
    0
Motor rating at AC-3, 400 V
  kWh 132
Characteristics
on the side: 2 x DILM820-XHI(V)11-SI; 2 x DILM820-XHI(V)11-SA
operating frequency
Squirrel-cage motor
Operating characteristics
Starting:from rest
Stopping:after attaining full running speed
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 1 x rated motor current
Utilization category
100 % AC-3
Typical applications
Compressors
Lifts
Mixers
Pumps
Escalators
Agitators
Fans
Conveyor belts
Centrifuges
Hinged flaps
Bucket-elevators
Air conditioning system
General drives in manufacturing and processing machines
Extreme switching duty
Squirrel-cage motor
Operating characteristics
Inching, plugging, reversing
Electrical characteristics
Make: up to 6 x rated motor current
Break: up to 6 x rated motor current
Utilization category
100 % AC-4
Typical applications
Printing presses
Wire-drawing machines
Centrifuges
Special drives for manufacturing and processing machines
Switching duty for non-motor loads, 3-pole, 4-pole
Operating characteristics
Non-inductive or slightly inductive loads
Electrical characteristics
Make: 1 x rated current
Break: 1 x rated current
Utilization category
100 % AC-1
Typical applications
Electric heat
Short-time loading, 3-pole
Time interval between two loading cycles: 15 minutes
Normal switching duty
Dimensions
DILM1000-XHI…-SI
DILM1000-XHI11-SA

Opis pochodzi ze strony www.moeller.net .